Commercial Control
- Indication for the screen:(Fig 1)
Fig 1
| No. | Instruction | No. | Instruction |
| 1 | Clock time | 8 | Drain symbol(displays when draining ) |
| 2 | Heating symbol (display when detected temp lower than setting temp) | 9 | Lack water symbol(displays when lack of water ) |
| 3 | Temp (lower than 0℃ display—L, higher than 70℃ display—H) | 10 | High temp symbol (when boiler overheats) |
| 4 | model:A 、B and AUTO model | 11 | fan(displays when fan is running) |
| 5 | Temp symbol (Celsius or Fahrenheit) | 12 | lamp(displays when lamp is on) |
| 6 | Temp keeping symbol(display when temperature higher than setting temperature) | 13 | Key lock symbol(displays when key-button was locked, then the setting is null, can only switch steam generator on/off, lamp and fan) |
| 7 | Descaling symbol (display when descaling, flash when clean the boiler | 14 | Timing symbol(display when you wet the steam generator to be turned on a certain time,only works under auto model) |
- setting and operation(when the key button hasn’t been locked
- when the controller is on, press
button,press “←”“→” to choose the function setting like Fig 2 status
Press “
” enter Fig 3 status, press “+””-”adjust the temp (35℃~60℃ or 95 ~140 ℉),if keep pressing the “+””-”, the temp will up or down very fast- Press “
” button to confirm the setting, otherwise it will exit after 20 seconds and the temp setting won’t be confirmed 。
- when the controller is on, press
- Setting working time
- when the steam generator is on, press the, see fig 4
Press “
” button enter Fig 5 status,press “+””-”adjust the time(15 minutes to 4 hours, longer then 4 hours will display “NO” ), if keep pressing the “+””-”, the time will up or down very fast- Press “
” button to confirm the setting, otherwise it will exit after 20 seconds and the time setting will not be confirmed
- Setting working model
- Press “
” button enter Fig 6,press “←””→” enter Fig 6
Press “
” button enter Fig 7 status,press “+””-” choose model(A B, AUTO),- Press “
” button to confirm the setting, otherwise it will exit after 20 seconds and the model setting won’t be confirmed.
- Press “
- Time –delay, turn on the steam generator
- Press “
”button,press “←””→” enter Fig 8
Press “
” enter Fig 9, press “←””→” choose the functions you want to setting (the symbol is flashing, then press the press “+””-” if keep pressing the “+””-”, the time will up or down very fast)
- Press “
- Instructions for the time –lapse to turn on the steam generator. Fig 10

| No. | instruction | No. | instruction |
| 1 | timer1(“√”means enabled,”X” means turn off) | 4 | Timer 2 (“√”means enabled,”X” means disabled) |
| 2 | Timer 1, turn on time (00:00~12:40) | 5 | Timer 2, turn on time 12:00~23:40) |
| 3 | Timer 1, turn off time (00:15~12:55) | 6 | Timer 2, turn off time (12:15~23:55) |
- press “
” button to confirm the setting, otherwise it will exit after 20 seconds and the setting won’t be confirmed
- Descaling
- Press button,press “←”“→” enter Fig 11
- Press menu enter FIG 12 status, press “←”“→” choose the functions you want to setting (the symbol will flash, then press “+”“-”. If kept pressed the “+”“-”, the settable time will move up or down very quickly.

- Descaling instruction Fig 13

| No. | Instruction |
| 1 | descaling(“√”means enabled, “X”means turn off) |
| 2 | Descaling begins from (00:00~23:00) |
| 3 | Finish begin from (00:00~23:00) |
- Press”menu” press “
” button to confirm the setting, otherwise it will exit after 20 seconds and the data setting won’t be confirmed
- Setting clock time
- press menu, enter fig 14
- press “
” button enter Fig 15 status, press “+””-”adjust time, if keep press button, the time changing will be faster - press”menu” press “
” button to confirm the setting, otherwise it will exit after 20 seconds and the data setting won’t be confirmed
- Exit the settings menu
- press “
” button and press “←””→”enter Fig 16 status
press “
” exit setting
- press “